Federal Explosives Storage Requirements
Storage Type |
Classes of Explosive Materials Which May be Stored Therein |
High Explosives |
|
High Explosives |
|
Type 3 |
High Explosives |
Low Explosives |
|
Blasting Agents |
*As a result of tests with electric blasting caps, it has been determined
that these blasting caps are not subject to sympathetic detonation. Therefore,
a Type 4 storage facility meets the necessary requirements for storage of
blasting caps that do not mass detonate.
Items |
Requirements |
Hinges and Hasps |
Shall be attached to doors by
|
Locks |
Each door shall be equipped with:
Locks shall be five-tumbler or five-blade. Padlocks shall be protected with 1/4 inch (.25") steel caps constructed to prevent sawing or lever action on locks/hasps.
NOTE: Outdoor/mobile storage facilities with one steel, case-hardened,
five-tumbler padlock, having at least a 3/a inch (.375") diameter shackle,
have been determined by the Director |
Lighting |
Electric lighting used in any magazine must meet National Electrical Code standards for conditions present. All electric switches must be located outside the magazine and comply with the National Electrical Code. Battery activated safety lighting may be used in all explosives magazines. |
Housekeeping |
Storage facilities shall be kept clean, dry, and free of grit, paper, empty
packages and containers, and rubbish.
Explosive materials shall not be placed directly against interior walls of a storage facility. Brooms and other cleaning utensils shall have no spark-producing metal parts. Only tools made of nonsparking materials shall be used in Types 1,2,3, and 4 magazines. (Metal slitters may be used for opening fiberboard containers. Metal tools other than nonsparking transfer conveyors shall not be stored in any magazine containing explosives.) Area surrounding storage facilities shall be kept clear of rubbish, brush, dry grass or trees less than 10' tall for not less than 25' in all directions. Any other combustible materials shall be kept a distance of not less than 50' from outdoor storage. |
A type 1 storage facility shall be a permanent structure: a building, an igloo or Army-type structure, a tunnel, or a dugout; and shall be bullet resistant, weather-resistant, theft-resistant, and well ventilated.
Item |
Requirements |
Masonry Wall |
Shall be constructed of:
*Hollow masonry units shall have all hollow spaces filled with well-tamped coarse dry sand or weak concrete. |
Metal Wall |
Sectional sheets of one of the following shall be securely fastened to a
metal framework:
Shall be lined with:
|
Wood Wall |
Exterior shall be covered with either:
Inner wall shall be constructed to provide not less than 6" between outer and inner walls; space filled with either:
|
Foundations |
Shall be constructed of:
(if piers or posts are used, space under |
Floors |
Shall be constructed of nonsparking material and shall be strong enough to bear weight of maximum quantity to be stored. |
Roof |
Outer roof (except fabricated metal roofs) shall be covered with:
|
Doors | Shall be constructed of 1/4" steel, AND shall be lined with 21 of hardwood. |
Hinges,Hasps, and Locks | See construction requirements common to all types of facilities. |
Interior |
Shall be constructed of, or covered with, a nonsparking material. No sparking metal construction shall be exposed below top of walls in interior. All nails shall be blind-nailed or countersunk. |
Ventilation |
Air space of 2" shall be left around ceiling and perimeter of floors, except at doorways. Foundation ventilators shall be not less than 4" x 6". Vents in foundation, root or gables shall be screened and offset, OR shielded. |
Ground | Ground around storage facility shall slope away for drainage. |
Igloos, Army Type Structures, Tunnels, Dugouts |
Shall be constructed of reinforced concrete, masonry, metal, or a combination
of these
Shall have an earthmound covering of Interior walls and floors shall be covered with a nonsparking material. Floor, door, lock, ventilation, exposed metal, and lighting requirements are as stated above. |
Lighting |
See construction requirements common to all types of facilities. |
Housekeeping | See housekeeping requirements common to all types of facilities. |
A type 2 storage facility shall be a box, a trailer, a semitrailer, or other mobile facility. It shall be bullet-resistant, fire-resistant, weather resistant, theft-resistant, and well ventilated.
Item |
Requirements |
Hinges,Hasps, and Locks | See construction requirements common to all types of facilities. |
Lighting | See construction requirements common to all types of facilities. |
Housekeeping | See housekeeping requirements common to all types of facilities. |
Restrictions on Type 2 Outdoor Storage Facilities |
|
Size | Shall be at least 1 cubic yard in size, or securely fastened to a fixed object. |
Ground |
Outdoor storage facilities shall be supported in such a manner so as to prevent
direct contact with the ground.
Ground around storage facility shall slope away for drainage. |
Construction | Sides, bottoms, tops, and covers or doors shall be constructed of .25" steel and lined with 2" of hardwood. |
Unattended Storage | Unattended vehicular storage facilities shall have wheels removed or shall be immobilized by kingpin locking devices. |
Restrictions on Type 2 Indoor Storage Facilities |
|
Location |
No indoor storage facility for storage of high explosives shall be located
in a residence or dwelling.
More than one magazine may be located in same building. No more than a total of 50 lbs. may be stored. Detonators must be stored in a separate magazine. |
Quantity Restrictions | No indoor storage facility shall contain a quantity of high explosives in excess of 50 pounds or more than 5,000 blasting caps. |
Construction |
Shall be of either:
WOOD (Shall have sides, bottoms, and covers or doors constructed of 2" hardwood and shall be well braced at corners. They shall be covered with sheet metal [not less than 26 gauge] and exposed nails shall be countersunk). METAL (Shall have sides, bottoms, and covers or doors constructed of 12-gauge metal and shall be lined inside with a nonsparking material. Edges of metal shall overlap sides at least 1"). |
Detonator Boxes |
|
Storage facilities for detonators in quantities of 100 or less shall have sides, bottoms, and covers constructed of 12 gauge metal, with hinges and hasps attached by welding. One five-tumbler lock shall be sufficient for locking purposes. |
A type 3 magazine is a "day-box" or other portable magazine. It must be fire-resistant, weather-resistant, and theft-resistant, but may be less than one cubic yard in size.
Items | Requirements |
Construction | Not less than 12-gauge (.1046 inch) steel, lined with 1/2" plywood or 1/2" hardboard. Door or lid must overlap door opening by at least one inch. |
Hinges,Hasps, and Locks | See housekeeping and construction requirements common to all types of facilities. |
Ground | Ground around storage facility shall slope away for drainage. |
Unattended Storage | Not allowed. Explosive materials must be removed to type 1 or 2 magazine. |
Lighting | See common requirements . |
Housekeeping | See common requirements . |
A type 4 storage facility may be a building, an igloo or Army-type structure,
a tunnel, a dugout, a box, a trailer, or a semi-trailer, or other mobile
facility. It shall be fire-resistant, weather-resistant, and theft-resistant.
Items | Requirements |
Construction |
Shall be of:
|
Doors or Covers
|
Shall be constructed of:
|
Foundations |
Shall be constructed of:
(if piers or posts are used, space under buildings shall be enclosed with metal.) |
Interior |
Shall be lined with nonsparking material.
No sparking metal construction shall be exposed below top of walls in interior. All nails shall be blind-nailed or counter-sunk. |
Hinges,Hasps, and Locks | See common requirements. |
Lighting | See common requirements. |
Housekeeping | See common requirements. |
Restrictions on Type 4 Outdoor Storage Facilities |
|
Ground | Ground around storage facility shall slope away for drainage. |
Unattended Storage | Unattended vehicular storage facilities shall have wheels removed or shall be Immobilized by kingpin locking devices. |
Restrictions on Type 4 Indoor Storage Facilities |
|
Location | No indoor storage facility for storage of low explosives shall be located in a residence or dwelling. |
Quantity Restrictions | No indoor storage facility shall contain a quantity of low explosives in excess of 50 pounds. |
A type 5 storage facility may be a building, an igloo or Army-type structure, a dugout, a bin, a box, a trailer, or a semi-trailer, or other mobile facility; and shall be weather-resistant and theft-resistant.
Items | Requirements |
Doors or Covers |
Shall be constructed of either
|
Hinges, Hasps, and Locks | One lock per door or cover. No hoods required on mobile units. |
Housekeeping | See construction requirements common to all types of facilities. |
Restrictions on Type 5 Outdoor Storage Facilities |
|
Ground | Ground around storage facility shall slope away for drainage. |
Unattended Storage | Unattended vehicular storage facilities shall have wheels removed or shall be Immobilized by kingpin locking devices. |
Restrictions on Type 5 Indoor Storage Facilities |
|
Location | No indoor storage facility for storage of blasting agents shall be located in a residence or dwelling. |